Lighting hardware locker manufacturers introduce the basic specifications for the standardization of custom assembly of European lamps and lanterns

2022-06-06 15:10:57
times

(If there are no special requirements for domestic sales, it will be implemented in accordance with this standard):


1. Classification:


CLASS0 lamps: Lamps that rely on basic insulation for protection against electric shock (basically not produced).


Class I lamps: The protection against electric shock of lamps not only relies on basic insulation, but also includes additional safety measures, namely ground wire protection.


CLASSⅡ: The electric shock protection of lamps depends not only on basic insulation, but also additional double insulation protection (regular requirements of our company).


CLASSⅢ: The protection against electric shock depends on the power supply voltage being a safe extra-low voltage, and no lamps with a voltage higher than SELV will be generated.


Second, the lighting hardware locker manufacturers introduce the basic requirements for assembly:


2.1 All electrical accessories must have VDE/CE certification (mark).

灯饰五金锁线器厂家

2.2 Class I lamps must be grounded; Class II lamps must be double-insulated; nipples and heat-shrinkable tubes are used for internal wiring to enhance insulation; the outlet of the lamp body is protected by rubber particles or yellow wax tubes; the lower part of the ground wire used must have internal teeth. Slip line, the surface cannot be inverted.


2.3 Use a parachute to strengthen the insulation protection of the plastic lamp tail; the lamp tail must be fixed with screws; the lower part of the terminal block used must have an insulating layer; there must be a locking device. All wires need to be wrapped with terminal blocks (preferred) or welded; the ground wire must be 2-3CM longer than the outlet wire; the wires used must not be damaged and the connection is firm; lamp head outlet: base to switch 30CM; floor lamp outlet: base to switch 50CM;


2.4 Tilt test: 15 degrees for table lamps, 8 degrees for floor lamps;


2.5 Lamp body test: withstand voltage test; on-off test; grounding test, etc. (high standard test); withstand voltage test: Class I lamps: 1500V; 10 mA; 1 second (the company's lower standard); Class II lamps: 4000V; 10MA; 1s


2.6 The desiccant should be put into the inner plastic bag; label requirements: watt label; country of origin label, etc.; manuals should be placed in the parts bag; wood screws; expansion screws, etc.;


Tags